COMFORTLINE INVERTER Heat Pump

Add to cart
  • Description
  • More details

COMFORTLINE INVERTER pool heat pumps are powered by an Inverter compressor, meaning it can intelligently adjust the heating capacity from 20% to 100% of its power according to different heating demands.

When the swimming pool season starts and heating demands are high, the COMFORTLINE INVERTER runs at 100% compressor power and fan speed for fast and optimal pool heating.
When the swimming pool reaches the required temperature, the COMFORTLINE INVERTER runs at low speed for energy saving with higher COP (Efficiency) to maintain the pool temperature.
At low speed, the COMFORTLINE INVERTER pool heat pump offers super quiet operation and you could also manually program its “Silence Mode”.

AVERAGE COP = 9 (at Air 26°C | Water 26°C | Humidity 80%)
COMFORTLINE INVERTER heat pump AVERAGE COP (Efficiency) is 9 at Air 26°C / Water 26°C / Humidity 80%, which means that 1 kW of electricity consumption can provide up to 9 kW of heating energy to your swimming pool in return. While On/Off (traditional) swimming pool heat pumps can only provide 5 kW of heating energy as its COP is just around 5.

2 YEARS GENERAL WARRANTY - 5 YEARS ON HEAT EXCHANGER AND COMPRESSOR

Personalized Recommendation

MODEL

BPN06

BPN08

BPN09

BPN13

BPN17

Recommended pool volume (m³)

15 - 30

20 - 40

25 - 45

30 - 60

40 - 75

Performance Condition: Air 26°C / Water 26°C / Humidity 80%

Heating capacity (kW)

6.5

8.0

9.2

12.5

16.5

COP

10.0 - 5.8

9.5 - 5.6

10.0 - 5.7

11.0 - 5.9

10.5 - 5.7

COP at 50% capacity

8,8

8,2

8,6

9,5

9,1

Performance Condition: Air 15°C / Water 26°C / Humidity 70%

Heating capacity (kW)

4.5

6.0

7.0

9.0

11.5

COP

6.1 - 4.25

6.1 - 4.1

6.2 - 4.3

6.1 - 4.2

6.2 - 4.2

COP at 50% capacity

6.0

6.1

5.8

6.0

6.2

Sound pressure at 1m dB(A)

39.8 - 51.2

40.8 - 51.1

40.6 - 52.5

42.9 - 53.0

45.2 - 56.3

Sound pressure of 50% capacity at 1m dB(A)

43.8

43.9

45.8

48.5

48.7

Sound pressure at 10m dB(A)

19.8 - 31.2

20.8 - 31.1

20.6 - 32.5

22.9 - 33.0

25.2 - 36.3

Rated input power at air 15°C (kW)

0.35 - 1.0

0.34 - 1.4

0.34 - 1.6

0.36 - 2.0

0.56 - 2.7

Rated input current at air 15°C (A)

1.52 - 4.4

1.48 - 6.0

1.48 - 7.0

1.57 - 8.7

2.43 - 11.7

Max input current (A)

6.5

8.0

9.5

12.5

15

Circuit breaker (A)

16

16

16

16

20

Power cord (mm²)

3×1.5

3×1.5

3×1.5

3×2.5

3×4

Power supply

230 V / Single-Phase / 50 Hz

Advised water flux (m³/h)

2 - 4

2 - 4

3 - 4

4 - 6

6 - 8

Water inlet/outlet connections (mm)

50 / 50

Net dimensions LxWxH (mm)

744×349×648

864×349×648

864×349×648

864×349×648

954×349×648

Net weight (kg)

42

46

47

49

60


The specified pool volumes are only valid for heating from April to October and the swimming pool should be covered during the night.
If these conditions are not met, please choose a larger model.